TY - JOUR
T1 - An assessment of the accuracy of electrolyte concentrations in neonatal parental nutrition
AU - Wright, J.
AU - Marriott, J.F.
AU - Langley, C.A.
AU - Wilson, K.A.
AU - Smith, J.
PY - 2002/9
Y1 - 2002/9
N2 - Focal pointsOver a six-week period in January and February 2002, 2ml samples were removed from all neonatal PN bags dispensedSamples were submitted for analysis of sodium, potassium and magnesium in triplicate by the hospital's clinical chemistry department using a Vitros Codac 950AT, dry slide, automated analyserOnly 19.3, 7.1 and 30.4 per cent of measured sodium, potassium and magnesium concentrations respectively deviated by £5 per cent from stated bag concentrationsThe results indicate that it is possible that some electrolyte concentrations included in neonatal PN vary significantly from stated values
AB - Focal pointsOver a six-week period in January and February 2002, 2ml samples were removed from all neonatal PN bags dispensedSamples were submitted for analysis of sodium, potassium and magnesium in triplicate by the hospital's clinical chemistry department using a Vitros Codac 950AT, dry slide, automated analyserOnly 19.3, 7.1 and 30.4 per cent of measured sodium, potassium and magnesium concentrations respectively deviated by £5 per cent from stated bag concentrationsThe results indicate that it is possible that some electrolyte concentrations included in neonatal PN vary significantly from stated values
UR - http://onlinelibrary.wiley.com/doi/10.1111/j.2042-7174.2002.tb00649.x/abstract
U2 - 10.1111/j.2042-7174.2002.tb00649.x
DO - 10.1111/j.2042-7174.2002.tb00649.x
M3 - Conference abstract
SN - 0961-7671
VL - 10
JO - International Journal of Pharmacy Practice
JF - International Journal of Pharmacy Practice
IS - S1
M1 - R46
T2 - British Pharmaceutical Conference 2002
Y2 - 23 September 2002 through 25 September 2002
ER -