T1 - Comparison of biomechanical parameters in penetrating keratoplasty and normal eyes using the Ocular Response Analyser
AU - Laiquzzaman, Mohammed
AU - Tambe, Katya
AU - Shah, Sunil
PY - 2010/11
Y1 - 2010/11
N2 - Background: To compare corneal hysteresis (CH) and corneal resistance factor (CRF) in eyes 1 year following penetrating keratoplasty (PK) with that of normal eyes using the Ocular Response Analyser.Methods: Prospective case comparison of 166 normal right eyes and 34 unilateral post-PK eyes presenting to a teaching hospital in Birmingham, UK. The CH, CRF and Goldmann-correlated intraocular pressure, of each eye was measured using the Ocular Response Analyser. The central corneal thickness (CCT) was measured using an ultrasonic pachymeter.Results: The mean CH was 10.6 ±2.0 mmHg, standard deviation (SD) and CRF was 10.2 ± 2.0 mmHg (SD) in normal eyes and 8.9 ± 3.3 mmHg and 8.1 ± 3.3 mmHg in post-PK eyes, respectively. The mean CCT was 541.8 ± 36.1 μm in normal eyes and 556.0 ±69.2 μm in post-PK eyes. The Goldmann-correlated intraocular pressure was 16.1 ± 3.1 mmHg and 12.4 ± 2.9 mmHg in normal eyes and post-PK eyes, respectively. The CCT was found to be higher in post-PK eyes compared with normal eyes but the difference was not statistically significant (P > 0.5).Conclusion: Reduced biomechanical measures were found in post-PK eyes despite a higher mean CCT. This may be due to the altered corneal structure following PK.
AB - Background: To compare corneal hysteresis (CH) and corneal resistance factor (CRF) in eyes 1 year following penetrating keratoplasty (PK) with that of normal eyes using the Ocular Response Analyser.Methods: Prospective case comparison of 166 normal right eyes and 34 unilateral post-PK eyes presenting to a teaching hospital in Birmingham, UK. The CH, CRF and Goldmann-correlated intraocular pressure, of each eye was measured using the Ocular Response Analyser. The central corneal thickness (CCT) was measured using an ultrasonic pachymeter.Results: The mean CH was 10.6 ±2.0 mmHg, standard deviation (SD) and CRF was 10.2 ± 2.0 mmHg (SD) in normal eyes and 8.9 ± 3.3 mmHg and 8.1 ± 3.3 mmHg in post-PK eyes, respectively. The mean CCT was 541.8 ± 36.1 μm in normal eyes and 556.0 ±69.2 μm in post-PK eyes. The Goldmann-correlated intraocular pressure was 16.1 ± 3.1 mmHg and 12.4 ± 2.9 mmHg in normal eyes and post-PK eyes, respectively. The CCT was found to be higher in post-PK eyes compared with normal eyes but the difference was not statistically significant (P > 0.5).Conclusion: Reduced biomechanical measures were found in post-PK eyes despite a higher mean CCT. This may be due to the altered corneal structure following PK.
KW - corneal resistance factor
KW - hysteresis
KW - penetrating keratoplasty
UR - http://www.scopus.com/inward/record.url?scp=78149472012&partnerID=8YFLogxK
UR - https://onlinelibrary.wiley.com/doi/full/10.1111/j.1442-9071.2010.02353.x
U2 - 10.1111/j.1442-9071.2010.02353.x
DO - 10.1111/j.1442-9071.2010.02353.x
M3 - Article
C2 - 20572823
AN - SCOPUS:78149472012
SN - 1442-6404
VL - 38
SP - 758
EP - 763
JO - Clinical and Experimental Ophthalmology
JF - Clinical and Experimental Ophthalmology
IS - 8
ER -