TY - JOUR
T1 - Corneal thickness in keratoconus
T2 - Comparing optical, ultrasound, and optical coherence tomography pachymetry
AU - Dutta, Debarun
AU - Rao, Harsha L.
AU - Addepalli, Uday K.
AU - Vaddavalli, Pravin K.
PY - 2013/3/1
Y1 - 2013/3/1
N2 - Purpose: To compare the central and peripheral pachymetry measurements determined using Orbscan IIz (Bausch & Lomb, Rochester, NY), Visante optical coherence tomography (OCT; Carl Zeiss Meditec, Dublin, CA), and RTVue OCT (Oculus Technologies, Wynwood, WA) with ultrasound pachymetry in eyes with established keratoconus and to evaluate the agreement between them. Design: Evaluation of diagnostic technologies. Participants: One hundred six eyes of 67 consecutive patients with a clinical diagnosis of keratoconus ranging in age from 12 to 40 years. Methods: Central corneal thickness (CCT) was determined by all the 4 techniques. Peripheral corneal thicknesses were determined using Orbscan IIz, Visante OCT, and RTVue at 8 points (superior, inferior, temporal, nasal, superior-temporal, inferior-temporal, superior-nasal, and inferior-nasal) all in the 5.0- to 7.0-mm arcuate zone. Main Outcome Measures: Central and peripheral keratoconus thickness. Results: Ultrasound pachymetry determined significantly higher CCT values than Orbscan IIz (P<0.001), Visante (P<0.001), and RTVue (P = 0.037), with a mean ± standard deviation difference of 14±3 μm, 13±2 μm, and 5±3 μm, respectively. The mean CCT difference was minimal (1±3 μm; P = 0.69) between the Orbscan IIz and Visante. A strong correlation was found (r>0.80) between all the CCT measurement techniques. Orbscan IIz significantly overestimated the peripheral thickness compared with the rest, and the mean differences ranged between 21 and 60 μm. Mean peripheral thickness differences between RTVue and Visante OCT always remained less than 20 μm. Weak correlations and larger limits of agreement were found between the techniques in thinner and peripheral zones. Conclusions: Orbscan IIz, Visante, RTVue, and ultrasound pachymetry show high correlation, although Orbscan IIz and Visante significantly underestimated CCT measurements compared with ultrasound pachymetry in keratoconus. Orbscan IIz significantly overestimated peripheral corneal thickness compared with RTVue and Visante. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article.
AB - Purpose: To compare the central and peripheral pachymetry measurements determined using Orbscan IIz (Bausch & Lomb, Rochester, NY), Visante optical coherence tomography (OCT; Carl Zeiss Meditec, Dublin, CA), and RTVue OCT (Oculus Technologies, Wynwood, WA) with ultrasound pachymetry in eyes with established keratoconus and to evaluate the agreement between them. Design: Evaluation of diagnostic technologies. Participants: One hundred six eyes of 67 consecutive patients with a clinical diagnosis of keratoconus ranging in age from 12 to 40 years. Methods: Central corneal thickness (CCT) was determined by all the 4 techniques. Peripheral corneal thicknesses were determined using Orbscan IIz, Visante OCT, and RTVue at 8 points (superior, inferior, temporal, nasal, superior-temporal, inferior-temporal, superior-nasal, and inferior-nasal) all in the 5.0- to 7.0-mm arcuate zone. Main Outcome Measures: Central and peripheral keratoconus thickness. Results: Ultrasound pachymetry determined significantly higher CCT values than Orbscan IIz (P<0.001), Visante (P<0.001), and RTVue (P = 0.037), with a mean ± standard deviation difference of 14±3 μm, 13±2 μm, and 5±3 μm, respectively. The mean CCT difference was minimal (1±3 μm; P = 0.69) between the Orbscan IIz and Visante. A strong correlation was found (r>0.80) between all the CCT measurement techniques. Orbscan IIz significantly overestimated the peripheral thickness compared with the rest, and the mean differences ranged between 21 and 60 μm. Mean peripheral thickness differences between RTVue and Visante OCT always remained less than 20 μm. Weak correlations and larger limits of agreement were found between the techniques in thinner and peripheral zones. Conclusions: Orbscan IIz, Visante, RTVue, and ultrasound pachymetry show high correlation, although Orbscan IIz and Visante significantly underestimated CCT measurements compared with ultrasound pachymetry in keratoconus. Orbscan IIz significantly overestimated peripheral corneal thickness compared with RTVue and Visante. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article.
UR - http://www.scopus.com/inward/record.url?scp=84875221993&partnerID=8YFLogxK
UR - https://www.sciencedirect.com/science/article/pii/S0161642012008469?via%3Dihub
U2 - 10.1016/j.ophtha.2012.08.036
DO - 10.1016/j.ophtha.2012.08.036
M3 - Article
C2 - 23177363
AN - SCOPUS:84875221993
SN - 0161-6420
VL - 120
SP - 457
EP - 463
JO - Ophthalmology- Journal of the American Academy of Ophthalmology
JF - Ophthalmology- Journal of the American Academy of Ophthalmology
IS - 3
ER -