TY - JOUR
T1 - Simultaneous continuous recording of accommodation and pupil size using the modified Shin-Nippon SRW-5000 autorefractor
AU - Wolffsohn, J.S.
AU - O'Donnell, C.
AU - Charman, W.N.
AU - Gilmartin, B.
PY - 2004/3
Y1 - 2004/3
N2 - The internal optics of the recent models of the Shin-Nippon SRW-5000 autorefractor (also marketed as the Grand Seiko WV-500) have been modified by the manufacturer so that the infrared measurement ring has been replaced by pairs of horizontal and vertical infrared bars, on either side of fixation. The binocular, open field-of-view, allowing the accommodative state to be objectively monitored while a natural environment is viewed, has made the SRW-5000 a valuable tool in further understanding the nature of the oculomotor response. It is shown that the root-mean-square of model eye measures was least (0.017 ± 0.002D) when the separation of the horizontal measurement bars were averaged twice. The separation of the horizontal bars changes by 3.59 pixels/dioptre (r2 = 0.99), allowing continuous on-line analysis of the refractive state at up to 60 Hz temporal resolution to an accuracy of <0.001D, with pupils >3 mm. The pupil edge is not obscured in the diagonal axis by the measurement bars, unlike the ring of the original optics, so in the newer model pupil size can be measured simultaneously at the same rate with a resolution of <0.001 mm. The measurements of accommodation and pupil size are relatively unaffected by eccentricity of viewing up to ±10° from the visual axis and instrument focusing inaccuracies over a range of 10 mm towards the eye and 5 mm away from the eye. The resolution and temporal properties of the analysis are therefore ideal for the simultaneous measurement of dynamic accommodation and pupil responses. © 2004 The College of Optometrists.
AB - The internal optics of the recent models of the Shin-Nippon SRW-5000 autorefractor (also marketed as the Grand Seiko WV-500) have been modified by the manufacturer so that the infrared measurement ring has been replaced by pairs of horizontal and vertical infrared bars, on either side of fixation. The binocular, open field-of-view, allowing the accommodative state to be objectively monitored while a natural environment is viewed, has made the SRW-5000 a valuable tool in further understanding the nature of the oculomotor response. It is shown that the root-mean-square of model eye measures was least (0.017 ± 0.002D) when the separation of the horizontal measurement bars were averaged twice. The separation of the horizontal bars changes by 3.59 pixels/dioptre (r2 = 0.99), allowing continuous on-line analysis of the refractive state at up to 60 Hz temporal resolution to an accuracy of <0.001D, with pupils >3 mm. The pupil edge is not obscured in the diagonal axis by the measurement bars, unlike the ring of the original optics, so in the newer model pupil size can be measured simultaneously at the same rate with a resolution of <0.001 mm. The measurements of accommodation and pupil size are relatively unaffected by eccentricity of viewing up to ±10° from the visual axis and instrument focusing inaccuracies over a range of 10 mm towards the eye and 5 mm away from the eye. The resolution and temporal properties of the analysis are therefore ideal for the simultaneous measurement of dynamic accommodation and pupil responses. © 2004 The College of Optometrists.
KW - accommodation
KW - autorefractor
KW - continuous
KW - dynamic
KW - pupil
UR - http://www.scopus.com/inward/record.url?scp=3142655869&partnerID=8YFLogxK
UR - http://onlinelibrary.wiley.com/doi/10.1111/j.1475-1313.2004.00186.x/abstract
U2 - 10.1111/j.1475-1313.2004.00186.x
DO - 10.1111/j.1475-1313.2004.00186.x
M3 - Article
C2 - 15005679
SN - 1475-1313
VL - 24
SP - 142
EP - 147
JO - Ophthalmic and Physiological Optics
JF - Ophthalmic and Physiological Optics
IS - 2
ER -