TY - JOUR
T1 - The frequency of vascular complications associated with the use of vascular closure devices varies by indication for cardiac catheterization.
AU - Stegemann, E
AU - Hoffmann, R
AU - Marso, S
AU - Stegemann, B
AU - Marx, N
AU - Lauer, T
PY - 2011/9
Y1 - 2011/9
N2 - Objective
This study aimed at exploring access site-related vascular complication rates associated with the use of the vascular closure device (VCD) Angio-Seal™ in an unselected patient population undergoing elective as well as emergency coronary angiography or intervention.
Background
The VCD Angio-Seal™ is widely used to achieve hemostasis after diagnostic and interventional cardiac procedures. There are only little data on the frequency of vascular complications after the use of the VCD Angio-Seal™ in patients in non-elective settings.
Method
In-hospital vascular complications were prospectively assessed in 4,653 consecutive cardiac catheterization procedures, which included 2,772 elective diagnostic and 960 elective percutaneous coronary interventions (PCI), and 921 emergency cardiac catheterizations in patients with NSTEMI/STEMI. In 2,077 procedures manual compression (MC) and in 2,576 procedures VCD was applied. Complication rates for manual compression and VCD use were studied and multivariate analyses performed to disclose predictors for access site-related vascular complications.
Results
Vascular complication rates in patients receiving MC to achieve hemostasis were similar to those receiving a VCD (MC 3.4% vs. VCD 3.2%, p = n.s.). Separate analysis of vascular complication rates for subgroups revealed a significant reduction in vascular complications for the PCI group using a VCD (MC 7.7% vs. VCD 3.2%, p = 0.003). In emergencies VCD use lead to a rise in vascular complications (MC 0.9% vs. VCD 6.3%, p < 0.001).
Conclusions
In contrast to elective settings, the risk of access site-related vascular complications is significantly increased after application of the VCD Angio-Seal™ in patients undergoing emergency catheterizations for NSTEMI/STEMI compared with manual compression.
AB - Objective
This study aimed at exploring access site-related vascular complication rates associated with the use of the vascular closure device (VCD) Angio-Seal™ in an unselected patient population undergoing elective as well as emergency coronary angiography or intervention.
Background
The VCD Angio-Seal™ is widely used to achieve hemostasis after diagnostic and interventional cardiac procedures. There are only little data on the frequency of vascular complications after the use of the VCD Angio-Seal™ in patients in non-elective settings.
Method
In-hospital vascular complications were prospectively assessed in 4,653 consecutive cardiac catheterization procedures, which included 2,772 elective diagnostic and 960 elective percutaneous coronary interventions (PCI), and 921 emergency cardiac catheterizations in patients with NSTEMI/STEMI. In 2,077 procedures manual compression (MC) and in 2,576 procedures VCD was applied. Complication rates for manual compression and VCD use were studied and multivariate analyses performed to disclose predictors for access site-related vascular complications.
Results
Vascular complication rates in patients receiving MC to achieve hemostasis were similar to those receiving a VCD (MC 3.4% vs. VCD 3.2%, p = n.s.). Separate analysis of vascular complication rates for subgroups revealed a significant reduction in vascular complications for the PCI group using a VCD (MC 7.7% vs. VCD 3.2%, p = 0.003). In emergencies VCD use lead to a rise in vascular complications (MC 0.9% vs. VCD 6.3%, p < 0.001).
Conclusions
In contrast to elective settings, the risk of access site-related vascular complications is significantly increased after application of the VCD Angio-Seal™ in patients undergoing emergency catheterizations for NSTEMI/STEMI compared with manual compression.
UR - http://europepmc.org/abstract/med/21479967
UR - https://link.springer.com/article/10.1007/s00392-011-0313-4
U2 - 10.1007/s00392-011-0313-4
DO - 10.1007/s00392-011-0313-4
M3 - Article
C2 - 21479967
SN - 1861-0684
VL - 100
SP - 789
EP - 795
JO - Clinical Research in Cardiology
JF - Clinical Research in Cardiology
IS - 9
ER -